What was found
CORROSION ON INBD, MID AND OTBD ATTACH FITTING FWD AND AFT BORES AT SLAT PANEL 3LT. CORROSION WERE REMOVED OF STA OUTB AND INBD HOLES WERE MEASURED 4EAS 0.1.126 THEREFORE OUT LIMIT MAXIMUM REWORK BUSHINGS WERE FABRICATED AND INSTALLED IAW ERA 531359-14, REV ORIG CORROSION WERE REMOVED STA MID, HOLES WERE MEASURED 4 EAS 0.938 BUSHINGS WERE FABRICATED AND INSTALLED IAW SRM 57-02, PAR 9.