What was found
CRACKED BEAM NR 1 FWD SECTION OF FWD SERVICE DOOR, R1, CUP PLATE, INNER SKIN, 2 INTERCOSTAL, 2 SUPPORTS, 2 CLIPS, 6 RETAINERS, SEAL AND BEAM WERE REMOVED IAW SRM 51-30-1, 51-30-2 AND 51-30-5. BEAM WAS DRILLED IAW SRM 51-10-4. BEAM HOLES WERE TREATED AND PAINTED IAW SRM 51-10-3. NEW BEAM WAS INSTALLED IAW SRM 51-30-2 AND 51-30-5.