What was found
CRACKED CLIP FWD /AFT EDGE OF BEAM N.1 LOWER SIDE AT FWD SERVICE DOOR. CRACKED CLIP FWD/AFT WERE REMOVED IAW SRM 51-30-5. NEW CLIPS WERE INSTALLED IAW SRM 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED CLIP FWD /AFT EDGE OF BEAM N.1 LOWER SIDE AT FWD SERVICE DOOR. CRACKED CLIP FWD/AFT WERE REMOVED IAW SRM 51-30-5. NEW CLIPS WERE INSTALLED IAW SRM 51-30-5.