What was found
CORROSION ON FLOOR STRUCTURE SECTION CONECTION AT AFT GALLEY AREA ON STRINGER 28L ON FRAME 67. L:0.340", W:0.530", D:0.002", MEASURES APPROXIMATELY SSI 534144. REPLACED SECTION CONNECTION AT AFT GALLEY AREA ON STR 28L ON FRAME .67 IAW SRM 51-72-11 AND DWG D53480505.