What was found
DENT ON FWD CARGO RT FRAME AT BS 700 ABOVE STR 24R. TRIMMED-OUT DENT ON FWD CARGO RT FRAME AT BS 700 ABOVE STR 24R AND ACCOMPLISHED A PERMANENT CAT"B" REPAIR IAW SRM 53-00-07, REPAIR 5, FIG 201. TRIMOUT MEASURE 9.040" X 1.080" X 0.5" RT THRESHOLD INSPECTION TO START AT OR BEFORE 41474 F/C & REPEAT INSPECTION EVERY 11000 F/C THEREAFTER. ACFT IS CURRENTLY AT 16474 F/C RER SRM 53-00-07, FIG 201, REPAIR 5, TABLE II, PAGE 210. METHOD OF INSPECTION: HFEC & DETAILED INSPECTION.