What was found
MAIN CABIN, FLOOR STRUCTURE INTERCOSTAL IS DAMAGED BETWEEN BS 860-879 BL0. REMOVED MAIN CABIN INTERCOSTAL ANGLE AT BS 860-879 BLO IAW SRM 51-40-02, FABRICATED INTERCOSTAL ANGLE IAW DWG 143N5157, REV: A, PN 7075-O .032, O.O. ST00006259 1" X 18" HEAT TREATED TO T6 CONDITION LOCATED & DRILLED INTERCOSTAL ANGLE IAW DWG 143N5157, REV A ALODINED, PRIMED AND TOP COATED & INSTALLED INTERCOSTAL ANGLE IAW SRM 51-40-02.