What was found
AFT PIT BILGE AREA; CORROSION FOUND AT BS 1460, S29L. REMOVED CORROSION AT AFT CARGO BAY BS 1460, S29L SPLICE IAW SRM 51-10-02, SPLICE WITH ORIGINAL THICKNESS OF .100 MATERIAL LOSS .033, MATERIAL REMAINING .067 FOUND TO BE OUT OF LIMITS IAW SRM 53-00-03. R & R STR SPLICE PN 146N3820-23, PO 00219 IAW DWG 146N3820, REV C INSTALLED SPLICE IAW DWG NR 146N3820, REV C AND SRM 51-40-02.