What was found
CORROSION AT AFT CARGO FLOOR SUPPORT AT BS 1412 BETWEEN STRINGERS 29 AND 30L. FOUND CORROSION TO BE WITH OUT LIMITS IAW SRM 53-00-04. FABRICATED A NEW FLOOR SUPPORT IAW SRM FAS 0115, REV .012 AND INSTALLED IAW DWG 146N5398, REV A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION AT AFT CARGO FLOOR SUPPORT AT BS 1412 BETWEEN STRINGERS 29 AND 30L. FOUND CORROSION TO BE WITH OUT LIMITS IAW SRM 53-00-04. FABRICATED A NEW FLOOR SUPPORT IAW SRM FAS 0115, REV .012 AND INSTALLED IAW DWG 146N5398, REV A.