What was found
MAIN CABIN FWD WET AREA FLOOR STUCTURE FOR FLIGHT CONTROL CABLES HAS CORROSION BS 338, LBL 22 1" X 1" CP 53-221-01. REMOVED CORROSION IAW SRM 51-10-2. FOUND TO BE OUT OF LIMITS 100 PERCENT MATERIAL LOSS IAW SRM 53-00-04. REMOVED WEB IAW SRM 51-40-02. FABRICATED NEW WEB FROM 7075-0 .040 IAW DWG 141N5170 REV C P O ST00004986 LOCATED AND DRILLED NEW WEB IAW SRM 51-40-05 AND 51-40-08. HEATED TREATED WEB TO 7075 T-6 IAW BAC5602. TREAT AND PRIMED WEB IAW SRM 51-10-2, INSTALLED NEW WEB IN MAIN CABIN WET AREA BS 338, LBL 22 IAW SRM 51-40-02.