What was found
MAIN CABIN L-2 DOOR AREA, LOWER FLOOR SUPPORT HAS CORROSION AROUND FASTENER LOCATIONS, 2" X 2". REMOVED CORROSION AS L-2 DOOR LOWER FLOOR SUPPORT IAW SRM 51-10-02 SUPPORT WITH ORIGINAL TICKNESS OF .125 MATERIAL LOSS .059, MATERIAL REMAINING .059, SUPPORT FOUND OUT OF LIMITS IAW SRM 53-30-15. LOCATED AND DRILLED NEW SUPPORT, PN 143N8328U53, PO 650DL-00306 IAW DWG 143N8522, REV D AND SRM 51-40-05 INSTALLED SUPPORT IAW DWG 143N8522, REV D AND SRM 51-40-02.