What was found
AFT CARGO BAY INTERCOSTAL CORRODED AT BS 1540-1560 S-26L. REMOVED INTERCOSTAL WEB FROM AFT PIT BS 1540-1560. 100 PERCENT MATERIAL LOSS IAW SRM 53-10-53. FAB NEW INTERCOSTAL 7075-0 .040 AND ANGLE 7075T6 .040. HEAT TREATED INTERCOSTAL. LOCATED AND DRILLED HOLE IAW DWG 146N5434, REV A. ALODINED & PRIMED BOTH IAW 51-20-01. TOP COATED BOTH INSTALL BOTH IAW DWG 146N54, REV A & DWG 146N5434, REV-ADCN, 001, 002, 003.