What was found
DUPLICATE ORIGINAL DAMAGED, MAIN CABIN FWD WET AREA CORROSION ON FLOORBEAM SURFACE BS 365, RBL 10 1" X 1" NUMEROUS SPOTS. CP53-222-01. REMOVED CORROSION FROM FLOORBEAM BS 365, FOUND MATERIAL LOSS OUT OF LIMITS IAW SRM 53-00-51, AD1, FIG 101, CUTOUT DAMAGED AREA FROM APPROXIMATELY LBL 60, RBL 60, FABRICATED REPAIR T-CAP FROM BAC1505-100880 7075-T6511 PO ST-00006343, 2 EA. APPROXIMATELY DIM 124" & 56", FABRICATED SPLICE ANGELS 4 EA FROM 7075-0 .063" POST-00006530, 2 EA & 7075-0 .090", 2 EA, PO 650DL-00167 APPROXIMATELY DIM 13.7500" & 19.2500", HEAT TREATED REPAIR ANGLES TO T6 CONDITION & INSTALLED REPAIR PARTS IAW SRM 53-00-51, REPAIR 9; SRM 51-40 -02; SRM 52-20-01 & BAC 5602. WORK IN PROGRESS. REMOVED CORROSION FROM FLOORBEAM BS 365, FOUND MATERIAL LOSS OUT OF LIMIT IAW SRM 53-00-51, FIG 101, CUTOUT DAMAGED AREA FROM APPROXIMATELY LBL 60, FABRICATED REPAIR T-CAP FROM BAC 1505- 100880 7075-T6511, PO ST-00006343, 2 EA APPROXIMATELY DIM 124" & 56", FABRICATED SPLICE ANGLE 4 EA. FROM 7075-O .063" PO ST-00006530, 2 EA & 7075-O .090", 2EA, PO 650DL-00165 APPROXIMATELY DIM 13. 7500" X 19.2500", HEAT TREATED REPAIR ANGLES TO T6 CONDITION & INSTALLED REPAIR PARTS IAW SRM 53-00-51, REPAIR 9, SRM 51-40 -02, SRM 51-20-01 & BAC 5602, INSTALLED REPAIR ID DECAL IAW PS 900-5-1, NR 04.