What was found
FLOOR FITTING BS 1720, RBL 50 HAS SEVERAL AREAS OF CORROSION. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS. REMOVED, LOCATED, DRILLED AND INSTALLED NEW FITTING IAW SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR FITTING BS 1720, RBL 50 HAS SEVERAL AREAS OF CORROSION. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS. REMOVED, LOCATED, DRILLED AND INSTALLED NEW FITTING IAW SRM.