What was found
UPPER CABIN FLOOR CUSP ANGLE AT BS 220, RBL 60 IS CORRODED AT UPPER SURFACE BLEND, CHECK LIMITS REF OR NRC 66531-0200-0115. BLENDED NOTED AREA IAW SRM 51-10-04, SECTION 26, FOUND TO BE IN LIMITS IAW SRM 53-00-00, FIG 103. REMOVED .013 FROM ORIGINAL .071 DEPTH GAUGE 3310. UPON REMOVAL OF CUSP WEB, FOUND TO BE CRACKED. REPLACED CUSP WEB IAW SRM 51-41-02, SECTION 4 AND 51-41-05, SECTION 3.