What was found
DENT AND GOUGES IN RT VERTICAL STABILIZER SKIN APPROXIMATELY 12" ABOVE FUSELAGE BETWEEN CS 1103 AND CS 1131. BLEND AREA OF PAINT FOR HFEC. REF SRM 53-01-01. ACCOMPLISHED HFEC INSPECTION OF BLENDED AREA IAW NDT SPM 06-10-01.001. NO CRACKS NOTED. ALODINE AND PRIMED ALL BARE AREAS. IDENTIFIED AS ENGINEERING APPROVED IAW ER/A 547104-14, REV ORIGINAL. REPAIRED SKIN IAW ER/A 547396-14-14, REV ORIGINAL. ER/A MATCHES ALL PRIS. CLOSED LOG AND REMOVED MONITOR INSPECTION IAW ALERT.