What was found
DAMAGE LOWER ANGLE AT LT CUSP WEB BETWEEN STA Y=889 AND STA Y=908 AND STA X=54 AND X=60 AT PASSENGER CABIN. DUCT OF ANTI-ICE SYS WAS REMOVED IAW AMM 30-10-07, PAGE BLOCK 401. SPLICE WAS REMOVED IAW SRM 51-41-05, SPLICE WAS FABRICATED IAW SRM 53-20-01, FIG 1, NEW ANGLE WAS INSTALLED IAW SRM 51-41-05, DUCT OF ANTI-ICE SYS WAS INSTALLED IAW AMM 30-10-07, PAGE 401. LEAK TEST WAS PERFORMED IAW AMM 30-10-00, AND NO LEAK WAS FOUND.