What was found
DURING TAXI IN, FIRST OFFICER`S WINDSHIELD HAD A LARGE SPARK. WINDSHIELD HEAT IS NO LONGER FUNCTIONING. FOUND THE WINDOW ANTI-FOG SENSOR LOOSE AND IN CONTACT WITH MOUNT SPRING. SECURED AND TESTED IAW AMM 30-41-01. OK FOR SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING TAXI IN, FIRST OFFICER`S WINDSHIELD HAD A LARGE SPARK. WINDSHIELD HEAT IS NO LONGER FUNCTIONING. FOUND THE WINDOW ANTI-FOG SENSOR LOOSE AND IN CONTACT WITH MOUNT SPRING. SECURED AND TESTED IAW AMM 30-41-01. OK FOR SERVICE.