What was found
PASSENGER CABIN, AFT WET AREA FLOOR STRUCTURE BS 1681, LBL 54 TO RBL 54, FLOORBEAM HAD SEVERAL NUT PLATE STRIPS CORRODED. REMOVED CORROSION IAW SRM 51-10-02, PG 12, PARA 15. BEYOND ALLOWABLE LIMITS OF SRM 53-00-51, FIG 101. CUT OUT THE DAMAGED AREA. FABRICATED AND INSTALLED A REPAIR IAW SRM 53-60-51, REPAIR 3.