What was found
AFT CARGO BAY CEILING BS 1420 TO 1440, BL 0, INTERCOSTAL UPPER FLANGE CRACKED AT FASTENER HOLES. REMOVED & REPLACED IAW SRM 51-40-02, PARA 4 (B), 4 (E), AND DWG 146N5180, REV. C.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO BAY CEILING BS 1420 TO 1440, BL 0, INTERCOSTAL UPPER FLANGE CRACKED AT FASTENER HOLES. REMOVED & REPLACED IAW SRM 51-40-02, PARA 4 (B), 4 (E), AND DWG 146N5180, REV. C.