What was found
SMALL AMOUNT OF SMOKE AND ODOR DETECTED FROM UNDER CAPTAIN'S DASHBOARD. REDUCED LIGHTS. SMOKE STOPPED. FOUND WIRE TERMINALS FOR BACK LIGHTNING FOR LANDING LIGHTS PANEL BURNT. RETERMINATED RING TERMINALS ON WIRES PER WDM CHAPTER 20. REINSTALLED WIRES ON CONNECTOR. PERFORMED NO-GO ODI PREVENTION IAW W/C 2120-2367. NO OTHER DEFECTS NOTED. PERFORMED LIGHTS CHECK ALL OP'S NORMAL. OK FOR SERVICE. (LP4182354)