As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DUE TO REPORTS FROM F/A OF SMOKE AND ODOR, PERFORM ODI ATA 2172 SMOKE FUME OF UNKNOWN SOURCE. C/W NO GO ODI W/C 2120-2367. FOUND WIRES ON BACK OF NO.2 COFFEEMAKER BY L-1 DOOR BURNT AND C/B POPPED. REPLACED COFFEMAKER PER MD88 AMM 25-36. LK AND OPS CK GOOD. SEE LOG NO. 4885180. (LP0952604)