As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FOUND APU GENERATOR LEAKING OIL DURING ODI PREVENTION. FOUND APU GENERATOR LEAKING OIL FROM CANNON PLUG AND WHERE IT MOUNTS TO THE GEARBOX. R/R APU GENERATOR PER A319 AMM 24-23 UP TO STEP F. WILL REQUIRE STEP G FOR COMPLETION. CONTINUE ON MEL. GENERATOR, ELEC OFF 32-2420-9-0003 03019 ON 32-2420-9-0003 10882. APU GENERATOR IN SERVICEABLE CONDITION. REFERENCE LOG #6298140.