What was found
SHIP 5656- ATB - DUE TO UNRELIABLE AIRSPEED AFTER T/O CAPT./STBY/FO (AIRSPEED). INVESTIGATION REVEALS WASP/BEE LODGED IN BOTH CAPT. AND FO PITOT PROBES. R/R CAPT. AND FO PITOT PROBES. PURGED AUX 1, FO AND CAPT. PITOT LINES. PERFORMED AOA SENSOR TEST, ALL READINGS GOOD AND SMOOTH DURING MOVEMENT. REPLACED RT ADC AND PERFORMED TEST 30 PITOT STATIC LEAK AND OPS TEST. ALL INDICATIONS NORMAL.