What was found
DURING INSPECTION, FOUND CORROSION ON FLOOR SUPPORT AT RBL 50 BETWEEN BS 951 TO 967. THE FLOOR SUPPORT WAS REPLACED IAW SRM 51-40-02 PAR 7, AND DWG 147A5660, REV B.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CORROSION ON FLOOR SUPPORT AT RBL 50 BETWEEN BS 951 TO 967. THE FLOOR SUPPORT WAS REPLACED IAW SRM 51-40-02 PAR 7, AND DWG 147A5660, REV B.