What was found
WHILE WORKING WRITE UP RT WING TO BODY LONGERON CRACK FOUND. REMOVED LONGERON 846371 COMPLETED WITH STEP ONE OF RI 583549-14 WIP329603 COMPLETED HFEC PER A220 ANDTP BD5000-A-J51-10-05-00AAA -353A-A ALL CRACKS MARKED QC2047 786880 COMPLETED STEP 4 AND 5 OF RI583549-14. COMPLETED STEP 5 OF RI 583549-14 QC 2047 COMPLETED WITH STEP 6-13 OF RI 583549-14 REV O COMPLETED SECTION 1 OF TIME LIMIT REPAIR PER ERA 583549-14 REV O. PLACING ON MON FOR REPETITIVE INSPECTION EVERY 150 HOURS TERMINATING IN 850 HRS .OK FOR SERVICE. ASSOCIATED ER/A 14-583549 ADDED FOR AC 8109. (LP# 6345734)