What was found
PAX DOOR 2R SLIDE INDICATION UNARMED PASSENGER DOORS NOT ARMED INDICATION MEL NUMBER ADDED FOR DISPATCH RELEASE, LOG REDEFERRAL REQUIRED. DOOR R2 SLIDE INDICATION DEFERRED PER A319 MEL 25-60-04D. ASSOCIATED ER/A 14-583984 ADDED FOR AC 3149 REMOVED 2R DOOR LINERS AND INSULATION BLANKETS. REMOVED 2R SLIDE PER AMDS 2561-4002-RA TO FACILITATE OTHER MAINTENANCE. WHILE PERFORMING DOOR RIG CHECK PER AMM 52-13, FOUND FWD LWR DOOR FRAME STOPS #'S 1 AND 2 WITH NO NUTS INSTALLED. STOPS #'S 1 AND 2 ARE PIVOTING AND SEPARATING FROM FRAME. STOPS #'S 3,4 ADN 5 FOUND WITH ANLY 2 NUTS INSTALLED ON EACH. PB 230249. REMOVED 1 THRU 5 FWD 2R DOOR STOOPS ON FR66. DNEVILLE 247288. PERFORMED HFEC PER ERA 583984-14 REF. A319 NTM 51-10-01-250-801. NO CRACK INDICATIONS FOUND. PER A319 AMM 52-13-31-400-00-2-A PARA 4. A & ERA 583984-14 REV ORIG. INSTALLED 2R LINER PER A319 AMM 25-23-45. RE-INSTALLED ORIGIONAL SLIDE REF LOG# 6433127. REPLACED FITTINGS 1,2,3 REINSTALLED FITTINGS 4,5.