What was found
CORROSION LEVEL: 2. CORROSION FLOORBEAM +Y1292 IN FR68 AT AFT GALLEY AREA. REPLACED FLOORBEAM +Y1292 IN FR 68 AT AFT GALLEY AREA (1EA) ASPER SRM 53-41-14-03A AND DWG D53472780. MEASURES OF CORROSION ARE L:0.729" W=0.638", D= 0.026".
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION LEVEL: 2. CORROSION FLOORBEAM +Y1292 IN FR68 AT AFT GALLEY AREA. REPLACED FLOORBEAM +Y1292 IN FR 68 AT AFT GALLEY AREA (1EA) ASPER SRM 53-41-14-03A AND DWG D53472780. MEASURES OF CORROSION ARE L:0.729" W=0.638", D= 0.026".