What was found
DENT EXTERNAL SKIN LOC AT FR 84 6 INCHES BETWEEN STR 2L TO STR 3L TAIL CONE UPPER FUSELAGE. CORRECTIVE ACTION: PERFORMED PERMANENT REPAIR ON EXTERNAL SKIN LOCATED AT FR 84, 6 INCHES BETWEEN STR 2L TO STR 3L TAIL CONE UPPER FUSELAGE, AS PER SRM A319 53-511-300-010.