What was found
DURING INSPECTION MAINTENANCE FOUND LEVEL 2 CORROSION ON ON STRINGER FLOOR SUPPORT STA BETWEEN 1360-1444, RBL 10.45 AT AFT CARGO COMPARTMENT (CCT). FLOOR SUPPORT REPLACED PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION MAINTENANCE FOUND LEVEL 2 CORROSION ON ON STRINGER FLOOR SUPPORT STA BETWEEN 1360-1444, RBL 10.45 AT AFT CARGO COMPARTMENT (CCT). FLOOR SUPPORT REPLACED PER SRM.