What was found
SHIP 3242 -ATB- DUE TO A L/G SHOCK ABSORBER FAULT AFTER ROTATION. CORRECTIVE ACTION: T/S FOUND R/H MLG H DIMENSION WAS 3 INCHES. TOP CHARGE VALVE PRESS. AT 1197 PSI AND BOTTOM AT 1200 PSI AT 52F. PER A320 AMM SERVICED R/H MLG FLUID AND NITROGEN, SERVICED L/H MLG WITH NITROGEN. REF CARD 1212-6050, SWUNG GEAR 4 TIMES, LEAK AND OPS CHECK GOOD.