What was found
SHIP 654 DURING WALKAROUND, FOUND DENT 34 INCHES BELOW L2 DOOR. CORRECTIVE ACTION: REMOVED DAMAGED AREA ABOVE NUMBER 21 STRINGER AT FRAME STATION 680, NO ADDITIONAL DAMAGE FOUND ON FRAME OR STRUCTURE. PERFORMED HFEC PER 757 NDT PART 6, 51-00-01-2R PROCEDURE 14. NO CRACK INDICATIONS PER STEP 3. FABRICATED DOUBLER AND FILLER PER B757 SRM 53-00-01-2R-14, STEP 4. OK TO TREAT & PRIME FILLER AND SKIN REPAIR PER SRM 53-00-01-2R PROCEDURE 14 STEP 5 THROUGH 6. INSTALLED NOTED REPAIR DOUBLER PER B757 SRM REF 53-00. RII INSTALLATION OF SRM REPAIR DOUBLER COMPLETE PER SRM 53-00-01. (6505018)