What was found
RT MLG FIXED O/B ATTACH AT TRUNNION FITTING CORRODED ON FWD AND AFT SIDES OF LUG. REMOVED LUG BUSHING AND MACHINED TO REMOVE CORROSION TO 1.502. WITHIN LIMITS PER OVERHAUL MANUAL 57-40-1. INSP RT MLG FIXED STRUT O/B ATTACH IAW B717 OHM 57-40-01 ITEM 6-C F.P.I. NO ITEMS (QC1315), FABRICATED OVERSIZED BUSHING, C/W MPI OF BUSHING, AND INSTALLED NEW BUSHING PER B717 OHM 57-40-1. CORROSION WORKED ON ERA 599950-14. RECIEVED FINAL ERA 599950-14 REV ORG. NO CHANGES NOTED. (LP #2270913)