What was found
DENT RIGHT SIDE FUSELAGE FORWARD OF FR 3 APPROX. 10" ABOVE R/H LOWER STRINGER. REMOVED DAMAGE EXISTING FASTENERS AND TRIMMED AREA PER A321 SRM 53-11-11 (P. PROUD 132081) 8-29-22, FABRICATED REPAIR DOUBLER, TREATED + PAINTED PER A321 SRM53-11-11 ( J. GEIST 346411) 8-29- 22. C/W STEPS OF ERA 601918-14 PRI REV. 0 (J. MAGILL 932089) C/W ERA/PRI 601918-14 REV 1. (J. MAGILL 932089) C/W ALL STEPS ERA 601918-14 REV. ORIG (J. MAGILL 932089) VERIFIED ERA 601718-14 REV ORIG MATCHES PRI 601918-14 REV 1. (LP# 2387597)