What was found
(LOG 2556569) DURING INSPECTION FOUND CORROSION ON FLOOR BEAM FROM STA 947 BTW RBL 50,LBL 50 AT W2 AREA RBL 50. FLOOR BEAM AT STA 947 AT RBL 50, LBL 50 AT W2 AREA WAS REPAIRED PER B737-900ER SRM 53-70-51-2R PROCEDURE 8, REPAIR 8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
(LOG 2556569) DURING INSPECTION FOUND CORROSION ON FLOOR BEAM FROM STA 947 BTW RBL 50,LBL 50 AT W2 AREA RBL 50. FLOOR BEAM AT STA 947 AT RBL 50, LBL 50 AT W2 AREA WAS REPAIRED PER B737-900ER SRM 53-70-51-2R PROCEDURE 8, REPAIR 8.