What was found
CRACK SHEAR PLATE BTW FR 69 TO FR 70 AT LEVEL FLOOR STRUCTURE AND AT L EVEL OF STR 23 R AT AFT GALLEY AREA. REPLACED SHEAR PLATE LOC BETWEEN FR 69 TO FR 70 AT LEVEL STR 23R FLOOR STRUCTURE AFT GALLEY AREA AS PER A321 SRM 51-72-11, SRM51 -42-11 AND DWG D53474180, RELEASE DATE 14-JUL-22, ISSUE Z. MEASURE OF CRACK IS L: 0.709 IN.