What was found
AFTER CORROSION REMOVAL AT THE EDGES OF LIGHTENING HOLE ON CUSP; WEBS AT STA Y=469, Y=508, Y=518, Y=527, Y=546, AND X=58 WERE FOUND OUT LIMITS PER B717 SRM 53-00-00-1A PROCEDURE ALLOWABLE DAMAGE GENERAL PAR. 4.A. SUMMARY OF NRC 00478: CORROSION LEVEL 2. CUSP WEBS AT STA Y=469, Y=508, Y=518, Y=527, Y=546, AND X=58 WERE REPAIRED PER B717 SRM 53-00-55-2R-4. (LP #2834361)