What was found
WARM RUBBERY SMELL AROUND DOOR 4L. NO ABNORMAL INDICATIONS AND ALL SYSTEMS NORMAL. TURNED OFF AFT COFFEE MAKERS AND PULLED CB'S . SMELL DISSAPEARED. C/W STEP 19 OF WORK CARD 0550-2002. FOUND NO EVIDENCE OF ARCHING /BURNT ELECTRICAL CONNECTORS/WIRES. AFT CARGO & FAN HAVE NO EVIDENCE OF ODOR OR DAMAGE. NO EVIDENCE IN BOTH AFT LAVS. NO EVIDENCE OF DAMAGE ON LAST 4 ROWS OF IFE OR LIGHTS. (778382 J. DOTY) FOUND BENT PRONG ON COFFEE MAKER 403. NO EVIDENCE OF ARCHING OR BURNT. (778382 J. DOTY) REMOVED & REPLACED AFT OTBD COFFEE MAKER PER A321 AMM 25-35. INSTALLED REPLACEMEMNT COFFEE MAKER PN: 4510-25UF00 SN: 656133903 ROBBED FROM SHIP 3709. OPS CHECK GOOD. OK FOR SVC. (LP# 4442586)