What was found
ELEC C/B TRIPPED IN CRUISE FLIGHT WITH ACRID ODOR, NEXT GOT COND R CAB VENT FAULT. COMPLIED WITH ECAM AND QRH, PACK FLOW TO HI, ODOR DISSIPATED. ECAM MSG "COND R CAB VENT FAULT" ATA212151 CLASS1 RECIRCULATION FAN RH. SOURCE VC. INSPECTED CABIN AREA AND CARGO, SDCU. NO ELEC SMELL. PERFORMED T/S. FOUND RCCB RECIRCULATION FAN TRIPPED. R RECIRCULATION FAN FAULT.