What was found
SHIP 659 IN REFERENCE TO RC 2040-0191-2L: DURING THE INSTALLATION, LOW PRESSURE ON EMERGENCY POWER RESERVOIR AT 2L DOOR WAS FOUND. CORRECTIVE ACTION: SUMMARY OF NRC 00312: EMERGENCY POWER RESERVOIR ASSY AT L2 DOOR WAS REPLACED. REMOVED PER B757-200 AMM 52-11 AND INSTALLED UNDER AMDS. (0643293)