As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SHIP 5645 R1 DOOR BUILDING HISTORY FOR HARD TO ARM. CORRECTIVE ACTION: T/S PER B757 FIM 52-11-00-815-813, FOUND MOORING LINE OUT OF PLACE. SECURED MOORING LINE PER B757 AMM 525-66, ALSO FOUND GIRT BAR DEFECTIVE. R/R R-1 GIRT BAR PER B757 AMM 25-66, OPS CHECK GOOD ARM/DISARM PER B757 AMM 52-11. (0845948)