What was found
MAINTENANCE FOUND DEFECT INDICATION ON FASTENER HOLE #3, #4, #8, #9, RH FWD DRAG FITTING AND SHIM MIGRATION. COMPLETED ER/A 628611-14 PRI REV 3 SECTION III. COMPLIED WITH ERA 628611-14AD REV ORIGINAL (1180021)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAINTENANCE FOUND DEFECT INDICATION ON FASTENER HOLE #3, #4, #8, #9, RH FWD DRAG FITTING AND SHIM MIGRATION. COMPLETED ER/A 628611-14 PRI REV 3 SECTION III. COMPLIED WITH ERA 628611-14AD REV ORIGINAL (1180021)