What was found
ON S/C FOUND EMERG LIGHTS INOP ROWS 10-15. FOUND WIRES PULLED FROM CONNECTOR AND SHORTED AT ROW 15. INSTALLED WIRES IN CONNECTOR. R/R POWER SUPPLY AT ROW 11 PER B737 M/M 33-51. OPS CKS GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ON S/C FOUND EMERG LIGHTS INOP ROWS 10-15. FOUND WIRES PULLED FROM CONNECTOR AND SHORTED AT ROW 15. INSTALLED WIRES IN CONNECTOR. R/R POWER SUPPLY AT ROW 11 PER B737 M/M 33-51. OPS CKS GOOD.