What was found
AUDIBLE POP AND SPARKS WHEN GROUND POWER CONNECTED. BURNING ODOR SMELLED IN FLIGHT DECK. GROUND POWER PROMPTLY REMOVED. PERFORMED ELECTRICAL CHECK OF K114. PHASES A AND B BOTH SHORTED FROM INPUT TO OUTPUT. R & R CONTACTOR K114 IAW AMM 24-41. R & R EXTERNAL POWER RECEPTACLE IAW AMM 24-41. R & R PHASE A & B INTERLOCK FUSES. RAN ON APU GENERATOR AND VERIFIED NO POWER TO RECEPTACLE. CONNECTED GROUND POWER & PERFORMED SEVERAL POWER SWAPS. ALL CHECKED GOOD.