What was found
SUPPLEMENTAL INFOMRATION, AIRCRAFT 5092, STRONG ELECTRICAL BURNING ODOR IN COCKPIT AND FORWARD GALLEY WHILE AT THE GATE. APU IN USE AND APU POWER AND BLEED OPERATIVE. FOUND FAN BLADES RUBBING ON HOUSING. FAN IS FREE SPINNING. PUT FAN DUCTING BACK ON IAW AMM 21-26. REMOVED & REPLACED AVIONIC FILTER IAW AMM 21-26. DEFERRED PER MEL 21-26-01A: LATE, REPLACED AVIONICS BLOWER FAN 20HQ.