What was found
AD RELATED, A.A. 5311-01216-04, AFT PASSENGER/CREW DOOR, FR68 LT, DOOR STOP FITTING NR 1, HOLE NR 4 (DIA. 0.250") HAD A CRACK INDICATION AT FRAME LAYER. EVALUATE & REPAIR IAW SRM 53-41-12. PERFORMED FREEZE PLUG REPAIR AT FR 68 DOOR FRAME STOP FITTING NR 1 HOLE NR 4 IAW SRM 53-41-12-300-010, FIGURE 001, AND FIGURE 001 & 002, REF:53-41-12-300-008 AND 51-73-12-801 REV. 155.00. : THIS IS CATEGOY B REPAIR WITH INSPECTION REQUIREMENT THRESHOLD FROM TIME OF ADL/REPAIR EMBODIMENT 24500 FC (FH NOT RELEVANT) SUBSEQUENT INSPECTION AT INTERVALS 10700 FC (FH NOT RELEVANT) INSPECTION METHOD HFEC I/A/W A319 SRM 53-41-12-205-009 PARG 2 TABLE 002. REV:155.00 DATED 17 NOV-25. FOR INSTALLATION OF THE DOORSTOP FITTING NR 1 SEE SPECIAL ITEM 9-31. (LP: 1426126)