What was found
UNREPAIRED EXISTING HOLES DIAMETER EQUAL TO OR GREATER THAN MINIMUM STARTING HOLE DIAMETER WAS FOUND. ON HOLES H1: 0.2634 IN , H2: 0.3321IN, H7: 0.2017 IN, H8: 0.2920 IN, HA:0.2027 IN, HB: 0.2620 IN, HC: 0.2030 IN, HD : 0.2631 IN, H9: 0.2032 IN, H10: 0.2631 IN, H11:0.2633 IN, H12: 0.3260 IN, H13: 0.2633 IN, H14: 0.3260 IN, H15:0.2631 IN, H16:0.32 59 IN, H17:0.2631 IN, H18: 0.3259 IN, H19:0.2631 IN LOC. FR16LH DOUBLE JOGGLE AREA. REPAIR IS REQUIRED PRIOR TO FURTHER FLIGHT. AMOC MAY BE REQUIRED. REFER TO AA 5311-01246-03A. AD RELATED. ER/A 567055-14AD REV F WAS VERIFIED AGAINST ER/A 567055-14AD REV F PRI REV 0 TO REV 4 AND WERE FOUND IN COMPLIANCE WITH THE SCOPE OF THE WORK ACCOMPLISHED, STEP RELATED TO ITEM 51 OF FINAL ER/A 567055-14AD REV F APPROVED DATE: 15/FEB/26 ARE DOCUMENTED ON THIS ORNRC AND PERFORMED ACCORDINGLY ON HOLES H1, H2, H7, H8, HA, HB, HC, HD, H9, H10, H11, H12, H13, H14, H15, H16, H17, H18 , H19 LOC. FR16LH DOUBLE JOGGLE AREA, RECHECK IS REQUIRED AT 6 MONTH ADDITIONAL ENGINEERING AUTHORIZATION IS REQUIRED FOR CONTINUE SERVICE BEYOND THIS LIMITS, FOR TIME CONTROLLED ITEMS. (LP: 1454207)