What was found
DURING C-CHK AND WHILE INSPECTING PER EM 5311-01246-01A AT FR16 LHS DOUBLE JOGGLE AREA EXISTING REPAIRSFOUND AT HOLES NR 3, 4, 5, & 6. ELONGATED HOLE NR 5 IN UCD LAYER. PER SECTION DTE OF 567055-14 REV F, THE REPAIR OF SECTION X IS LIMITED TO 6 MONTHS SERVICE (180 DAYS) FROM SECTION X (14FEB26). ADDITIONAL ENG'G AUTHORIZATION REQUIRED FOR SERVICE BEYOND THIS LIMIT. ASSOCIATED (LP: 1451734)