What was found
OXYGEN PANEL AT ROW 27 ABC DID NOT DROP WHILE WORKING CARD 2527- 01041-02. FOUND JUMPER BETWEEN SPEAKER AND PSU, BROKEN. REMOVED SND REPLACED JUMPER HARNESS IAW AMM 25-25-23. OPS CHECK GOOD. (LP: 8464026)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
OXYGEN PANEL AT ROW 27 ABC DID NOT DROP WHILE WORKING CARD 2527- 01041-02. FOUND JUMPER BETWEEN SPEAKER AND PSU, BROKEN. REMOVED SND REPLACED JUMPER HARNESS IAW AMM 25-25-23. OPS CHECK GOOD. (LP: 8464026)