What was found
CRACK INDICATION ON WINDOW FRAME NR 2, LOWER NODE ATTACHMENT AREA CONTINUITY FITTING LT SIDE, CRACK LENGTH IS 0.200. CRACK DIRECTION IS VERTICAL. COMPLIED WITH ER/A 632268-14AD REV ORIGINAL MATCHES WITH ALL STEPS OF ER/A 632268-14AD PRI REV 0 AND REV 1, PERFORMED REPAIR INSTRUCTIONS ON WINDSHIELD CENTER POST LOWER ATTACHMENT CONTINUITY FITTINGS IAW ER/A 632268- 14AD, REV ORIGINAL, SECTION I. RECHECK IS REQUIRED THE REPAIR IS TIME LIMITED TO 61,196 TFC (TFH NOT RELEVANT) FOR TIME CONTROLLED ITEM SEE SECTION DTE AND LOG PAGE # 1508218 AS PER ER/A 632268-14AD REV ORIGINAL.