What was found
AT D CK, NR 1 ENGINE AFT FIXED COWL HAS APROX 4 INCH CRACK AT FWD FRAME I/B FLANGE AT UPPER EDGE OF COWL. CUTOUT DAMAGED AREA PER B727 SRM 54-10-3 FIG 5. ACCOMPLISHED HFEC INSPECTION OF CUTOUT, VERIFIED CRACK REMOVED. INSTALLED REPAIR PER B727 SRM 54-10-3 FIG 5. REF: N/R 6592.